Abus-technologies Log Box-DA Data Logger Manuale Utente Pagina 7

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 25
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 6
ABUS TECHNOLOGIES INC.
7
Log Box-DA
Note: The case cover should not be opened unless battery replacement is required. If this is the case,
the cover must be properly tightened back in its place such as to assure the IP67 / 68 protection.
IP67/IP68 external connectors
CHANNEL CABLE (RIGHT)
CONNECTION
Blue Channel 1 - IN1 - positive (+)
Black Channel 1 - GND - negative (-)
White Channel 2 - IN2 - positive (+)
Brown Channel 2 - GND - negative (-)
SWITCH CABLE (LEFT) CONNECTION
Blue Transducer +V TRANS
Black External Battery (-BAT)
White External Battery (+BAT)
Brown Not Connected